Price
$2,242.00 CAD
Stock
50+ In Stock

  • Model - 224
  • Switch Option - Standard SPDT Switch
  • Factory Set Point - No Factory Set Point
  • Tag - Paper ID Tag
  • Cleaning - Without Cleaning

Specifications

Adjustment Type

  • Factory Set (Pre-Set) One Switch

Ambient Temperature Range

  • -40° to 71° C (-40° to 160° F)

Applications

  • Anesthesia Equipment
  • OEM Applications
  • Plasma Cutting
  • Sterilizers

Approvals & Certifications

  • ISO 9001

Approvals & Certifications

  • CE
  • CSA C22.2 No. 14, File # E42272
  • Low Voltage Directive (LVD) 2006/95/EC
  • PED: 97/23/EC
  • UEC Compliant to LVD
  • UL (C,US) 508

Deadband

  • psi: 0.2 to 2.3 (kPa: 1.38 to 15.86, Mbar: 13.8 to 158.6)

Electrical Connectors

  • Direct to Switch Terminals

Electrical Contacts

  • Gold Contacts, 1 A at 125 Vac Resistive
  • Normally Closed
  • Normally Open

Electrical Rating

  • 1 A at 125 Vac Resistive
  • 10 A 125 Vdc or Vac Resistive, Deadband & Min. Set Point Will Increase
  • Adjustable Deadband, 15 A at 125/250/277 Vac Resistive
  • Close Deadband, 5 A at 125/250 Vac Resistive
  • High Ambient, 15 A at 125/250 Vac Resistive, Temperature -17.78° to 121° C (0° to 250° F)

Enclosure, Body Details

  • Skeleton Construction

Mounting

  • 1/4” NPT Female

Name Plate, Tag Material

  • Stainless Steel, Paper ID Tag & Wire Attachment

NPT Connection

  • 1/4” NPT Female

Process Connection Material

  • Phosphor Bronze Bellows with Brass Pressure Connection

Proof Pressure

  • psi: 30 to 110 (kPa: 206.8 to 758.4, bar: 2.1 to 7.6)

Repeatability

  • Set Point Repeatability: ± 1 % of Full Scale Range

Service

  • Oxygen Service Cleaning, Alcohol Cleaning to Remove Residue from the Process Connection

Set Point - Decreasing

  • bar: 0 to 6.9
  • kPa: 0 to 689.5
  • psi: 0 to 100

Set Point - Increasing

  • bar: 0 to 6.9
  • kPa: 0 to 689.5
  • psi: 0 to 100

Shock

  • Set Point Repeats after 15 G, 10 millisecond Duration

Storage Temperature

  • -54° to 71° C (-65° to 160° F)

Switch Type

  • One SPDT

System Pressure

  • bar: 7.6
  • kPa: 758
  • psi: 110

Vibration

  • Set Point Repeats after 2.5 G, 5 to 500 CPS
show more