Series: One Series 2SLP49 Models K10 to K13 Differential Pressure Transmitter Brand: United Electric Controls Ltd
Price
$170.00
CAD
Stock
50+ In Stock
- Model - K10
- Certificate - Certificate of Conformance
- Seals - Single Seal
- Adjustments - Standard Adjustment
- Unit - kg/cm²
- Tag - Stainless Steel Tag
- Mounting Bracket - No Mounting Bracket
- Service - Oxygen Cleaning Service
- Adapter - 1/4” Female NPT to G1/2” Male
Specifications
Accuracy
- 0.5 % of Full Range Span
Ambient Temperature Range
- -40° to 70° C (-40° to 158° F)
Applications
- Filter Monitoring
- Hydraulic Oil Pressure
- Lubricating Oil Monitoring
- Pumps & Compressors
Approvals & Certifications
- ATEX
- ATEX CE: EN 61000-6-2, EN 61000-6-4
- CRN
- IEC 61508: 2010
- IEC Ex
- INMETRO
- NAMUR NE 43
- RoHS
- TS
- UL (C,US)
Approvals & Certifications
- Emission: EN 61000-6-4 Class A, Immunity: EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3 (Continuous Radiated Disturbances), EN 61000-4-4 (Electrical Fast Transients), EN 61000-4-5 (Surges), EN 61000-4-6 (Continuous Conducted Disturbances), EN 61000
- FMEDA
- FS
- ISO 9001
- KCS
- SIL 2,3 Certification
BSP Connection
- G 1/2” Male
Circuit Protection
- EMI/RFI Immunity
Communication
- HART
Compensated Temperature
- -20° to 50° C (-4° to 122° F)
Cover Material
- Polyester Painted Aluminum with Tempered Glass Insert
Diaphragm Material
- 316L Stainless Steel
Display
- 4-Digit x 0.5” (12.7 mm) Backlit LCD
Electrical Connectors
- 3/4” NPT Female
Enclosure Finish
- Epoxy Powder-Coated
Enclosure, Body Material
- 360 Aluminum Alloy
Environmental Protection
- Explosion-proof
- Flameproof
- IP66
- NEMA 4X
Fill Material
- Silicone Oil
Input
- Power Input: 4-20 mA Analog Input Powered (20-40 Vdc) or Direct Connection to 24 Vdc
Mounting
- Pipe Mounting Bracket
- Wall Mounting Bracket
Name Plate, Tag Material
- Stainless Steel
NPT Connection
- 1/4” NPT Female
- 1/4” NPT Male
Operating Pressure
- Maximum
Operating Temperature
- -40° to 70° C (-40° to 158° F)
- Display Operating Temperature Range: -12° to 70° C (10° to 158° F)
Output
- 24 Vdc, 360 ohms, Max.
- Analog Signal & IAW Status Output: 4-20 mA
Output Format
- Switch Output
Overpressure & Static Pressure Limits
- Overpressure, Max.
Pressure Range
- bar: 0 to 13.8
- kPa: 0 to 1,380
- psi: 0 to 200
Pressure Type
- Differential
Process Temperature
- Maximum
Relay Output
- 0 to 130 Vdc, 2.5 A (General to purpose)
Repeatability
- 0.1 % of Full Range Span
Response Time
- Analog Output Response Time: 250 milliseconds, Max.
- Display Response Time: 400 milliseconds (2.5 Hz)
- Switch Response Time: ≤ 100 milliseconds for Detection of Full Step Change & Change of Output State, Filter Feature Off
Service
- Oxygen Cleaning Service
Shock
- 15 G, 10 milliseconds Duration
- 40 G, 6 milliseconds
- MIL-STD-810 G, Effect < ± 0.40 % of Range
Stability
- Long Term Stability: ± 0.25 % of Range Per Year, Max.
Thermal Drift
- 0.03 % of Full Scale/°C
Vibration
- 5 G at 10 to 1,000 Hz
Vibration Effect
- < ± 0.40 % of Range
Wetted Materials
- 316 Stainless Steel
- 316L Stainless Steel