6KFP431K0X8XXCA1

Series: AF-600 FP - Fan and Pump Drives Brand: General Electric
Price
$1,095.00 CAD
Stock
25+ In Stock

  • Input Voltage - 400 V, 50/60 Hz
  • Input Phase - 3-Phase
  • HP Rating - 1000 HP
  • Enclosure Type - IP00/Open
  • A1 / B1 RFI Filter - Only A2 RFI Filter Installed
  • Conformal Coating - Conformal Coatings
  • Version - 1st Version

Specifications

Environmental Conditions

Enclosures

  • IP20 Chassis
  • IP54
  • IP55
  • IP21
  • IP00 Chassis

Installation Location

  • For use at altitudes of 1000 m or Less without derating.

Storage Temperature

  • -25° to 65° C

Ambient Temperature

  • 10° to +50° C for above 45° C, there will be derating

Ambient Humidity

  • 5 to 95 % Relative Humidity, Non-Condensing

Vibration

  • 1.0 G

Cooling Method

  • Fan Cooled all ratings. Fan Control auto, 50 % level, 75 % level, 100 % level Adjustable

Standards

Approvals & Certifications

  • Suitable for use on a Circuit capable of delivering not more than 100,000 RMS symmetrical amperes for 230 V and 400 V.
  • C-Tick
  • cUL
  • UL
  • CE

Input Power Supply

Rated Input AC Voltage

  • 525-690 Vac, 3-Phase, 50/60 Hz, ± 10 % V
  • 380-480 Vac, 3-Phase, 50/60 Hz, ± 10 % V
  • 200-240 Vac, 3-Phase, 50/60 Hz, ± 10 % V

Maximum Voltage Imbalance

  • 3 % of rated Supply Voltage

True Power Factor

  • > 0.9 Nominal at Rated Load

Displacement Power Factor

  • > 0.98

Switching on Input Power Supply

  • Maximum twice/minute up to 7.5 kW
  • Maximum once/minute above 7.5 kW

Environment According to EN60664-1

  • Overvoltage Category III/Pollution Degree 2

DC Link Reactors

  • Built-In DC Link Reactors on all ratings

RFI Filters

  • Built-In RFI Filters to reduce noise generated by the drive

Output

Rated Output Voltage

  • 0 to 100 % of Supply Voltage

Output Frequency

  • 0 to 590 Hz

Switching on Output

  • Unlimited

Acceleration / Deceleration Time

  • 1-3600 seconds

Control Method

  • Sinusoidal PWM Control (V/Hz, Avd. vector Control)

Control

Starting Torque

  • 110 % Starting torque for 1 minute (Variable torque)

Carrier Frequency (Motor Noise, KHz)

  • 16
  • 14
  • 12
  • 10
  • 8
  • 7
  • 6
  • 5
  • 4
  • 3.5
  • 3
  • 2
  • 1.5
  • 1
  • 2.5

Torque Boost

  • 0 to 300 % setting to compensate voltage in relation to the load at low speed

Acceleration / Deceleration Time

  • 0.01-3600 seconds (4 acceleration and deceleration times are selectable via digital inputs. Acceleration and deceleration patterns can be selected from linear or S-Curve)

Data Protection

  • Password Protection for quick menu or main menu, 0-9999

Pattern Operation

  • Settings via built-in logic Controller sequencer

Jump Frequency Control

  • 4 jump (or skip) frequencies via Parameter set to avoid mechanical vibration

Slip Compensation

  • Maintains motor at constant speed with load fluctuations

Torque Limit Control

  • Output torque can be controlled within a Range of 0.0 to 110 % (0.1 and steps)

Preset Speeds

  • 8 Programmable preset speeds selectable by 3 digital inputs

Built-In Communications

  • Apogee FLN P1
  • Metasys N2
  • Modbus RTU
  • Drive RS-485

Trim Reference Setting

  • Available for speed reference offset via potentiometer, Voltage Input, or Current Input

DC Injection Braking

  • Braking level: 0-100 % of rated Current
  • Braking Time: 0.0-60.0 seconds
  • Starting frequency: 0.0-590 Hz

Auto-Restart After Power Failure

  • Restarts the drive without stopping after instantaneous Power failure

Jogging Operation

  • Operation via on Key or Digital Input (Forward or Reverse)

Energy Savings

  • Controls output voltage to minimize motor loss during constant speed operation

Start Mode Function

  • This functionality smoothly catches a Spinning motor

Fire Override Mode

  • Overrides drive’s Protective features and keeps motor running

Pump Cascade Controller

  • Distributes running hours evenly over up to 4 pumps

Sleep Mode

  • Drive detects Low or no fl ow conditions and Adjusts output

Dry Pump Detection

  • Detects pump Operation and can set off Alarm, shuts off, or other Programmed actions

Belt Monitoring

  • Drive can detect Relationship between Current and speed to recognize a broken belt

Real Time Clock

  • With Programmable timed actions

Logic Controller (LC) Sequencer

Logic Controller Events

  • Up to 38 Programmable events

Comparators

  • Array of 6 comparators

Timers

  • Array of 8 timers, Adjustable from 0.0 to 3600 sec

Logic Rules

  • Array of 6 boolean logic rules

Logic Controller States

  • Array of 20 logic Controller action States

Process Controller (PID)

Controller

  • 4 Auto Tune PID Controllers Built-in

Feedback Select

  • Up to 2 references. Selectable - no function, motor feedback, separate encoder, encoder option module, or resolver option module

Anti Windup

  • Enabled
  • Disabled

Start Speed

  • 0.0-200 Hz

Proportional Gain

  • 0.00-10.00

Integral Time

  • 0.1 - 10000.0 millisecond

Differential Time

  • 0.0 - 10 s

Differential Gain

  • 1.0-50.00

Feed Forward Factor

  • 0 to 500 %

On Reference Bandwidth

  • 0 to 200 %

Operation

Operation Method

  • Communications: RS-485 Modbus RTU, Metasys N2, and Apogee FLN P1 USB Port for Programming drive with optional PC Software
  • Keypad Operation: Hand, off, auto Digital Input: Programmable for Start/stop, forward/reverse, jog timer Operation: Stop after predetermined time frame

Frequency Reference Signal

  • 0/4-20 mA Analog Input
  • 0-10 Vdc Analog Input
  • Speed Potentiometer: 0 to +10 Vdc, 10 to 0 Vdc
  • Left or right arrow Buttons on keypad in manual mode

References

  • Up to 3 Input references can be selected from analogue Input #1 or #2, frequency Input #1 or #2, network, or potentiometer

Output Signals

  • 2x Digital Outputs 24 Vdc (Digital outputs are used in place of 2 of the digital inputs)
  • 2x form C Relays rated to 2A at 230 Vac
  • 1x analog output 0/4-20 mA

Protective Functions

  • Line Phase Loss
  • Serial Comms Bus Fault
  • Hardware Mismatch
  • Speed Limit
  • Auto Tuning Fault
  • Soft Charge Fault
  • No Motor
  • Keypad Error
  • DC Overvoltage
  • DC Undervoltage
  • Drive Overload
  • Motor Overtemperature
  • Motor Thermistor Overtemperature
  • Torque Limit
  • Overcurrent
  • Ground Fault
  • Short Circuit
  • Control Word Timeout
  • Brake Resistor Short-CCircuited
  • Brake Chopper Short-Circuited
  • Brake Check
  • DC Link Voltage High
  • Internal Fan Fault
  • External Fan Fault
  • Power Board Overtemperature
  • Missing U Phase
  • Missing V Phase
  • Missing W Phase
  • Internal Fault
  • Control Votlage Fault
  • Auto Tune Check - Wrong Motor Parameters
  • Auto Tune Low Onom - Motor Current is too Low
  • Current Limit
  • Mechanical Brake Low
  • Drive Initialized to Default Value
  • DC Link Voltage Low

Keypad

Keypad Features

  • LCD display with 6 alpha-numeric lines
  • Multi-language support
  • Hot pluggable, remote Mount option, and copycat Feature, IP65 rating when remote Mounted on Enclosure
  • LED’s - Green - drive is on, Yellow - indicates a warning, Red - indicates an Alarm, amber - indicates active menu keys and H-O-A keys

Password

  • 2 level password Protection

Alternate Motor Parameters

  • Up to 4 separate complete Parameter set-Ups are available

Graphical Trending

  • Trend Speed
  • Power
  • Frequency

RS-485 Modbus RTU Serial Communications

Physical Level

  • EIA/RS-485

Transmission Distance

  • 500 m

Node Address

  • 32

Transmission Speed

  • 2400
  • 4800
  • 9600
  • 19200
  • 38400
  • 115200

Transmission Mode

  • Half Duplex

Transmission Protocol

  • Modbus RTU

Character Code

  • Binary

Character Length

  • 8-bits

Error Check

  • CRC

Mounting Clearance

  • All AF-600 FP drives can be Mounted
  • side-by-side without Spacing. for all drives rated 90 kW or below Allow 100 mm free Space above and below
  • For all drives rated 110 kW and above Allow 225 mm free Space above and below

Documentation

show more