  • Input Voltage - 230 V, 50/60 Hz
  • HP Rating - 100 HP
  • Enclosure Type - IP55/NEMA 12
  • RFI Filter - A1/B1 RFI Filter Installed
  • Brake Chopper - Factory Installed Brake Chopper
  • Conformal Coating - No Conformal Coatings
  • Version - 1st Version

Specifications

Environmental Conditions

Enclosures

  • IP20 Chassis
  • IP00 Chassis
  • IP21
  • IP55
  • IP54
  • IP66

Installation Location

  • For use at altitudes of 1000 m or Less without derating

Storage Temperature

  • -25° to 65° C

Ambient Temperature

  • -10° to +50° C for above 45° C, there will be derating: please consult GE

Ambient Humidity

  • 5 to 95 % Relative Humidity, Non-Condensing

Vibration

  • 1.0 G

Cooling Method

  • Fan Cooled all ratings. Fan Control auto, 50 % level, 75 % level, 100 % level Adjustable

Standards

Approvals & Certifications

  • CE
  • UL
  • cUL
  • C-Tick
  • Suitable for use on a Circuit capable of delivering not more than 100,000 RMS symmetrical amperes for 230 V and 400 V.

Input Power Supply

Rated Input AC Voltage

  • 200-240 Vac, 3-Phase, 50/60 Hz, ± 10 % V
  • 380-480 Vac, 3-Phase, 50/60 Hz, ± 10 % V
  • 525-690 Vac, 3-Phase, 50/60 Hz, ± 10 % V

Maximum Voltage Imbalance

  • 3 % of rated Supply Voltage

True Power Factor

  • > 0.9 at Rated Load

Displacement Power Factor

  • > 0.98

Switching on Input Power Supply

  • Maximum twice/minute up to 7.5 kW
  • Maximum once/minute above 7.5 kW

Environment According to EN60664-1

  • Overvoltage Category III/Pollution Degree 2

Output

Rated Output Voltage

  • 0 to 100 % of Supply Voltage

Output Frequency

  • 0 to 590 Hz

Switching on Output

  • Unlimited

Acceleration / Deceleration Time

  • 0.01-3600 seconds

Overload Current Rating

  • Sinusoidal PWM Control (V/Hz, Avd. vector Control, Sensorless vector, and fl ux vector with motor feedback)

Control

Starting Torque

  • 110 % Starting torque for 1 minute (Variable torque)
  • 160 % Starting torque for 1 minute (Constant torque)

Carrier Frequency (Motor Noise, KHz)

  • 1.5
  • 2
  • 2.5
  • 3
  • 3.5
  • 4
  • 5
  • 6
  • 7
  • 8
  • 10
  • 12
  • 14
  • 1
  • 16

Torque Boost

  • Selectable by up to 5 individual V/Hz settings in V/Hz Mode or by 0 - 300 % setting of torque boost Parameter in Adv. vector mode

Acceleration / Deceleration Time

  • 0.01-3600 seconds (4 acceleration and deceleration times are selectable via digital inputs. Acceleration and deceleration patterns can be selected from linear or deceleration patterns can be selected from linear or S-Curve)

Data Protection

  • Passw Protection for quick menu or main menu, 0-9999.

Pattern Operation

  • Settings via built-in logic Controller sequencer

Jump Frequency Control

  • 4 jump (or skip) frequencies via Parameter set to avoid mechanical vibration

Slip Compensation

  • Maintains motor at constant speed with load fluctuations

Torque Limit Control

  • Output torque can be controlled within a Range of 0.0 to 160 % (0.1 and steps)

Preset Speeds

  • 8 Programmable preset speeds selectable by 3 digital inputs

Trim Reference Setting

  • Available for speed reference offset via potentiometer, Voltage Input, or Current Input

DC Injection Braking

  • Starting frequency: 0.0-590 Hz
  • Braking Time: 0.0-60.0 seconds
  • Braking level: 0-100 % of rated Current

Jogging Operation

  • Operation via on Key or Digital Input (Forward or Reverse)

Auto-Restart After Power Failure

  • Restarts the drive without stopping after instantaneous Power failure

Energy Savings

  • Controls output voltage to minimize motor loss during constant speed operation

Start Mode Function

  • This functionality smoothly catches a Spinning motor

Logic Controller (LC)

Logic Controller Events

  • Up to 37 Types of Programmable events

Comparators

  • Array of 6 comparators

Timers

  • Array of 8 timers, Adjustable from 0.0 to 3600 sec

Logic Rules

  • Array of 6 boolean logic rules

Logic Controller States

  • Array of 20 logic Controller action States

Process Controller (PID)

Feedback Select

  • Resolver Option Module
  • Encoder Option Module
  • Motor Feedback
  • No Function
  • Separate Encoder

Anti Windup

  • Enabled
  • Disabled

Start Speed

  • 0.0-200 Hz

Proportional Gain

  • 0.00-10.00

Integral Time

  • 0.1 - 10000.0 millisecond

Differential Time

  • 0.0 - 10 s

Differential Gain

  • 1.0-50.00

Feed Forward Factor

  • 0 to 500 %

On Reference Bandwidth

  • 0 to 200 %

Operation

Operation Method

  • USB Port for Programming drive with optional PC Software
  • Built-In RS-485 Modbud
  • Jog Timer Operation: Stop after predetermined time frame
  • Auto Digital Input: Proframmable for Start/stop, forward/reverse
  • Keypad Operation: Hand Off

Frequency Reference Signal

  • 0/4-20 mA Analog Input
  • 0-10 Vdc Analog Input
  • Speed Potentiometer: 0 to +10 Vdc, 10 to 0 Vdc
  • Left or right arrow Buttons on keypad in manual mode

References

  • frequency Input #1 or #2, network, or potentiometer
  • Up to 3 Input references can be selected from analog Input #1 or #2

Input Signals

  • 2x analog Inputs -10 to +10 V scalable or 0/4-20 mA scalable
  • 2x pulse Inputs rated to 110 kHz or 1x pulse Input and 1 - encoder Input 24 Vdc rated to 4096 PPR
  • 1x safe stop Digital Input suitable for category 3 installations to meet EN-954-1
  • 6x Digital Inputs, 24 Vdc PNP or NPN

Output Signals

  • 1x analog output 0/4-20 mA
  • 2x Digital Outputs 24 Vdc (Digital outputs are used in place of 2 of the digital inputs)
  • 2x form C Relays rated to 2A at 230 Vac

Keypad

Protective Functions

  • DC Link Voltage High
  • Brake Check
  • Brake Chopper Short Circuited
  • Brake Resistor Short Circuited
  • Control Word Timeout
  • Short Circuit
  • DC Link Voltage Low
  • Ground Fault
  • Torque Limit
  • Motor Thermistor Overtemperature
  • Motor Overtemperature
  • Drive Overload
  • DC Undervoltage
  • DC Overvoltage
  • Overcurrent
  • Internal Fan Fault
  • External Fan Fault
  • Power Board Overtemperature
  • Serial Comms Bus Fault
  • Auto Tuning Fault
  • Soft Charge Fault
  • No Motor
  • Keypad Error
  • Drive Initialzied to Defualt Value
  • Mechanical Brake Low
  • Current Limit
  • Auto Tune Low Inom - Motor Current is Too Low
  • Auto Tune Check - Wrong Motor Parameters
  • Control Voltage Fault
  • Internal Fault
  • Missing W Phase
  • Missing V Phase
  • Missing U Phase
  • Line Phase Loss
  • Hardware Mismatch
  • Speed Limit

Keypad Features

  • LCd Display with 6 Alpha-numberic Lines
  • LED Amber (Active Menu Keys)
  • LED Red (Alarm)
  • LED Yellow (Warning)
  • LED Green (ON)
  • IP65 Rating when Remote Mounted on Enclosure
  • Copycat Feature
  • Remote Mount Option
  • Hot Pluggable
  • Multi-language Support

Password

  • 2 Level Password Protection

Alternate Motor Parameters

  • Up to 4 separate complete Parameter set-Ups are available

Graphical Trending

  • Trend speed, Power, frequency or any value Programmed in Status display

RS-485 Modbus RTU Serial Communications

Physical Level

  • EIA/RS-485

Transmission Distance

  • 500 m

Node Address

  • 32

Transmission Speed (bits/s)

  • 115200
  • 38400
  • 19200
  • 9600
  • 4800
  • 2400

Transmission Mode

  • Half Duplex

Transmission Protocol

  • Modbus RTU

Character Code

  • Binary

Character Length

  • 8-bits

Error Check

  • CRC

Mounting Clearance

  • All AF-650 GP drives can be Mounted side-by-side without Spacing
  • For all drives rated 75 kW or below Allow 100 mm free Space above and below
  • For all drives rated 90 kW and above Allow 225 mm free Space above and below

Documentation