Prism PI Diaphragm Valve Controller

Brand: Valmet

The Prism PI integrates an advanced position sensing system and integral pneumatic control for sanitary diaphragm and other linear applications. 

Compact and durable, the PI is suited for corrosive, heavy washdown and hazardous areas.
Features
  • Suitable for high pressure washdown and temporary submersion, the PI is rated for NEMA 4, 4X and 6 (IP66 & IP67)
  • Screw-on cover enables convenient access without tools
  • Enclosure is made of high impact strength, corrosion resistant polycarbonate
  • Prominent visual indicator boldly displays mechanical position status
  • Low profile design minimizes height clearance required above actuator
  • All electronics are sealed inside the linear C-module to protect against contamination, shock and vibration
  • Intelligent high accuracy position sensor is solid state with no moving parts for long life. Sensor automatically adjusts dead band based on stroke length

Specifications

Brand

Accuracy

  • 0.040” (1 mm) - Position Sensor System

Actuator Type

  • Pneumatic
  • Spring Return

Approvals & Certifications

  • CE
  • CEC
  • IEC
  • NAMUR
  • NEC

Communication

  • ASI Communication Protocol
  • Baud Rate: 125, 250, 500 Kbps - DeviceNet (92S & 92W)
  • Bluetooth
  • DeviceNet

Conduit Connection

  • 1/2” NPT Female
  • M20 Female
  • Micro Connector (4-Pin, 5-Pin, 6-Pin)
  • Mini Connector (4-Pin, 5-Pin, 6-Pin)

Configuration

  • 3-Way, 2-Position, Spring Return - Solenoid Valve
  • 4-20 mA Auxiliary Analog Input - DeviceNet (92S & 92W)
  • Discrete Input - DeviceNet (92S & 92W), AS-Interface (96S) & AS-Interface with Extended Addressing (97S & 97W)
  • Power Output - DeviceNet (92S & 92W), AS-Interface with Extended Addressing (97S & 97W)
  • Remote Sensor Setting - DeviceNet (92S & 92W)
  • Wink Feature - DeviceNet (92S & 92W), AS-Interface (96S) & AS-Interface with Extended Addressing (97S & 97W)

Cover Material

  • Polycarbonate

Current

  • Maximum
  • Minimum on Current: 2 mA - Stainless Steel Switching Sensor
  • Target Off I > 3 mA - NAMUR Sensor
  • Target on I < 1 mA - NAMUR Sensor

Electrical Contacts

  • Normally Closed
  • Normally Open

Electrical Rating

  • 1 W at 120 Vac - Solenoid Valve
  • 1 W at 24 Vdc - Solenoid Valve
  • 12 mA at 120 Vac - Solenoid Valve
  • 20 mA at 24 Vdc - Solenoid Valve
  • Maximum

Enclosure, Body Material

  • Fiber Reinforced Polycarbonate

Environmental Protection

  • IP66
  • IP67
  • NEMA 4
  • NEMA 4X
  • NEMA 6

Filter

  • 40 microns - Solenoid Valve

Flow Rate

  • 0.1 to 0.2 Cv - Solenoid Valve

Indication

  • Position Status: LED

Input

  • Auxiliary: 24 Vdc at 2.5 mA (Self-Powered) - AS-Interface (96S) & AS-Interface with Extended Addressing (97S & 97W)

Materials of Construction

  • Actuator Fasteners, Shaft Coupler, Valve Manifold: Stainless Steel
  • Trigger System (Magnetic): Polysulfone with Black Chromated Zinc Reinforcement

NPT Connection

  • 1/8” NPT Female

Operating Pressure

  • psi: 25 to 140 (kPa: 172.4 to 965.27, bar: 1.7 to 9.7) - Solenoid Valve

Operating Temperature

  • -10° to 50° C (14° to 122° F) - Pneumatic Valve (1KS, 1MS)
  • -20° to 60° C (-4° to 140° F) - Pneumatic Valve (11S, 1NS)

Operation

  • Normally Open (Solid State)

Output

  • 2 W at 24 Vdc - AS-Interface (96S) & AS-Interface with Extended Addressing (97S & 97W)
  • 21-26 Vdc - AS-Interface (96S) & AS-Interface with Extended Addressing (97S & 97W)
  • 24 Vdc (Input Voltage Ranging from 10-24 Vdc) - DeviceNet (92S & 92W)
  • 4 W at 24 Vdc Both Outputs Combined - DeviceNet (92S & 92W), AS-Interface (96S) & AS-Interface with Extended Addressing (97S & 97W)

Override

  • Manual Override

Power

  • Transmit Power: 2.5 mW or 4 dBm - Wireless Link

Pressure Cycles

  • Operating Life: over 1 Million - Pneumatic Valve

Range

  • 330 feet (100 metres) - Wireless Link

Repeatability

  • 0.020” (0.5 mm) - Position Sensor System

Response Time

  • Set (Closed, Open): 2 seconds

Seat / Seal Material

  • Seal: Reinforced Stainless Steel

Valve Size

  • 1/4” to 2” (8 to 50 mm)
  • 1/4” to 6” (8 to 150 mm)

Valve Type

  • Diaphragm Valve
  • Solenoid Valve

Voltage

  • 20-125 Vac/dc - Stainless Steel Switching Sensor
  • 7-24 Vdc - NAMUR Sensor

Voltage Drop

  • 7.5 V at 100 mA - Max.
  • Maximum

show more