CW57 Radar Level Meter

Brand: BM Technologies

CW57 for liquids Applications: Measurement of highly erosive liquids in food and medical industry.

Anticorrosion and anticoagulation antenna. The Radar level meters of BM compact and Remote wave 26 Ghz series are excellent devices for no contact level measurement.

The microwave impulses, emitted by the radar’s antenna, travel at speed of light and a part of their energy, reflected by the surface of the medium to be measured, is received by the same antenna.

The period of time (flying time) between the emission and the arrival of the impulses, is proportional to the existing distance between the antenna and the surface of the medium to be measured.

Specifications

Accuracy

  • ± 0.12” (± 3 mm)

Approvals & Certifications

  • ISO 9001
  • TÜV

Cable Entry

  • 1 x PG 13.5
  • 1/2” NPT
  • M20 x 1.5

Communication

  • Output Signal: HART

Consumption

  • Absorption: 2 W for Supply 4-Wires Version
  • Absorption: 22.5 mA - Max.
  • Absorption: Max.

Current

  • Fixed Signal for Anomaly: 20.5 mA
  • Fixed Signal for Anomaly: 22 mA
  • Fixed Signal for Anomaly: 3.8 mA

Display

  • Resolution Display: 0.039” (1 mm)

Enclosure, Body Material

  • 316L Stainless Steel
  • Aluminum
  • Plastic PBT-FR

Environmental Protection

  • IP66
  • IP67

Flange Material

  • AISI 316L Stainless Steel
  • PTFE

Flange Size - 2” (DN 50)

  • 2” (DN 50) - Unrated

Flange Size - 3” (DN 80)

  • 3” (DN 80) - Unrated

Flange Size - 4” (DN 100)

  • 4” (DN 100) - Unrated

Flange Size - 6” (DN 150)

  • 6” (DN 150) - Unrated

Frequency

  • 26 GHz
  • Resistance to Vibration: 10 to 150 Hz
  • Ripple Allowed: 100 to 100,000 Hz for Supply 2-Wires Version

Humidity

  • < 95 % Relative Humidity

Input

  • Input Voltage: 15-36 Vdc for Supply 2-Wires Version
  • Input Voltage: 230 Vac ± 10 % for Supply 4-Wires Version
  • Input Voltage: 24 Vdc ± 10 % for Supply 4-Wires Version

Materials of Construction

  • Antenna: 316L Stainless Steel
  • Antenna: PTFE

Measuring Range

  • 0 to 65.62 feet (0 to 20 metres)

Measuring Time

  • Interval of Measuring: Approximately 1 second

Operating Pressure

  • psi: -14.5 to 72.52 (kPa: -100 to 500, bar: -1 to 5)

Operating Temperature

  • -40° to 150° C (-40° to 302° F)

Output

  • Output Signal: 4-20 mA (2 & 4-Wires)

Process Connection Material

  • 316L Stainless Steel

Resistance

  • Maximum

Resolution

  • 1.6 µA

Rotation

  • Beam Angle: Ø 50 > 18°
  • Beam Angle: Ø 80 to 150 > 10°

Storage Temperature

  • -40° to 80° C (-40° to 176° F)

Supply Voltage

  • 198-242 Vac
  • 22.8-26.4 Vdc

Update Time

  • Integration Time: 0 to 20 seconds
  • Interval of Updating: Approximately 1 second
show more