6180 AeroDAQ Secure Graphic Recorder for AMS2750D
Brand: EurothermThe 6180 AeroDAQ is designed to meet the specifications of the aerospace industry.
Automated scheduling of TUS (Temperature Uniformity Survey), SAT (System Accuracy Test), and instrument calibration is handled by the AeroDAQ based on furnace class and instrument type as per the relevant tables of AMS2750D.
A Service Page clearly displays the number of days until the next activity is due with messages to alert that the due date is approaching.
Features- Colour touchscreen display
- USB 'plug and play'
- 6 universal Inputs
- 32 MB non-volatile flash memory
- 125 ms parallel sampling
- Compact flash
- Modbus RTU
- Ethernet TCP/IP
- Web server
- EtherNet/IP server
- Multi-language support (Including Chinese, Korean and Cyrillic)
Specifications
Brand
Approvals & Certifications
- CE
- EMC
- Emissions & Immunity: BS EN 61326
- IEC 584.1, 751
- UL (C): E57766
Cable Length
- Ethernet Communication: Max.
Channels
- 0 to 48
- Maths, Totalisers & Counters: 36 to 128 Virtual Channels
- Virtual Channels: 36
Circuit Protection
- Open Circuit Detection: ± 57 NA, Max.
- Over Voltage Protection (OVP)
Cold Junction Reference
- External
- Internal
- Off
- Remote
Communication
- 2 USB Ports at Rear
- ASCII Protocol
- BOOTP
- DHCP
- EtherNet/IP Server
- FTP
- ICMP
- IEEE 802.3
- Modbus RTU Master & Slave
- SMTP
- SNTP
- TCP/IP Protocols
- Transmission Standard: EIA-232
- Transmission Standard: EIA-485
Current
- Bias Current: 0.05 NA
- Maximum
Display
- Size & Resolution: XGA (1024 x 768 Pixels) 12.1”
- TFT Color LCD with Cold Cathode Backlight
Electrical Connectors
- CAT5 Cable
- Termination: RJ45
Electrical Rating
- Output: 2 A at 250 V, 500 VA
Environmental Protection
- Bezel & Display: IP66
- Sleeve: IP20
Humidity
- Operation: 5 to 80 % Relative Humidity
- Storage: 5 to 90 % Relative Humidity
Input
- -150 mV to 20 V
- -20 to 20 Vdc Thermocouples Dc mV
- Channel to Channel: 2,500 Vac (Dielectric Strength)
- Channel to Ground: 1,500 Vac (Dielectric Strength)
- Input/Relay Output Sample Rate: 10 Hz
- Maximum
- Potentiometer
Input Impedance
- 20 V Range: 65.3 kiloohms
- 38 mV, 150 mV, 1 V Ranges: > 10 megaohms
Insulation
- Terminals to Ground: 50 Vrms or Dc (Basic Insulation)
Insulation Resistance
- > 10 megaohms at 500 Vdc
Isolation
- Channel to Channel, Channel to Ground, Relay to Relay, Relay to Ground: 300 Vrms (Double, Basic Insulation)
Linearization
- RTD Typical of, Max.
- Thermocouple Typical of, Max.
Mounting
- Panel Mount DIN 43700
Operating Temperature
- 0° to 50° C (32° to 122° F)
Power
- Maximum
Power Requirement
- Low Voltage Option: 20-42 Vrms, 45 to 400 Hz
- Low Voltage Option: 20-54 Vdc
- Poly-Carbonmonofluoride / Lithium Batteries
Power Supply
- 20-42 Vac (20-54 Vdc)
- 90-264 Vac (110-370 Vdc) 47 to 63 Hz
Resistance
- Input (Min. Break Resistance): 10 megaohms
- Input: 0 to 600 ohms
- Shunt Value: 100 to 250 ohms
Resolution
- Input: 1.4 to 720 µV
- Input: 5 to 148 milliohms
RTD Type
- Cu10
- Cu53
- JPt100
- Ni100
- Ni120
- Pt100
- Pt1000
- Pt100A
Sensor, Probe Connection
- 2-Wire RTD
- 3-Wire RTD
Sensor, Probe Type
- B Thermocouple
- C Thermocouple
- D Thermocouple
- E Thermocouple
- G2 Thermocouple
- J Thermocouple
- K Thermocouple
- L Thermocouple
- Ni/NiMo Thermocouple
- NiMo/NiCo Thermocouple
- N Thermocouple
- PL2 Thermocouple
- R Thermocouple
- S Thermocouple
- T Thermocouple
- U Thermocouple
Shock
- BS EN 61010
Storage Temperature
- -20° to 60° C (-4° to 140° F)
Supply Voltage
- 110-370 Vdc
- 85-265 Vac, 47 to 63 Hz
Temperature Effect
- Worst Case Temperature Performance Input Per °C: 25 to 388 ppm
Temperature Range
- RTD Typical: -220° to 850° C (-364° to 1,562° F)
- Thermocouple Typical: -270° to 2,495° C (-454° to 4,523° F)
Vibration
- (10 to 150 Hz), BS EN 60873
Voltage
- Maximum
- The Rate Impulse Voltage for Equipment on Nominal 230 V Mains is 2,500 V