I-Series Ultrasonic Level Sensor
Brand: BM TechnologiesThe I-Series Sensors can be used to measure distance, level, empty space or volumes of liquids and bulk solids.
They are used wherever highly accurate level measurements are required. NIVUS I-Sensors are designed for use under poor ambient conditions.
Pollution and wear are prevented thanks to non-contacting measurement technology. Housed in one common and fully encapsulated enclosure, sensor and transmitter can be installed easily at low space requirements.
Pre-programmed measurement range steps make comprehensive programming works unnecessary.
The NIVUS I-Sensor can be connected directly to any PLC, NIVUS GPRS Data Loggers and other systems processing readings as soon as an active mA-input or Hart communication protocol is available.
Specifications
Brand
Applications
- Bulk Solids
- Data Loggers
- Drinking Water
- Flood Protection
- Industrial Applications
- Level Measurement
- Power Generation Equipment
- Volumes of Liquids
- Wastewater
Approvals & Certifications
- ATEX for Zone 1 & Zone 0, II 2 GD Ex M IIC T4, II 1 GD Ex ia IIC T4
Cable Length
- 0 to 3,281 feet (0 to 1,000 metres)
Communication
- HART
Configuration
- Agitator Avoidance
- Echo Evaluation
- Linearisation
- PC Software for Parameter Setting
Consumption
- Low Power Consumption: 10-28 Vdc
- Low Power Consumption: 4-20 mA
Enclosure, Body Material
- Sensor: PVDF
- Sensor: Valox 357 PBT
Environmental Protection
- IP68
Frequency
- 1,200 to 2,200 Hz
- 125 kHz for I-3 Sensor
- 41 kHz for I-15 Sensor
- 50 kHz for I-10 Sensor
- 75 kHz for I-6 Sensor
Function
- Distance
- Empty Space
- Level
- Linearization Using 16 BreakPoints
- Volume
Materials of Construction
- Sensor Face Coating: PTFE
- Sensor Face Coating: Soft Foam
Measuring Range
- 0.07” (2 mm) for I-3 Sensor & 0.07” (2 mm) at Distance of 0 to 6 metres for I-10 Sensor
- 0.41 to 9.84 feet (0.125 to 3 metres) for I-3 Sensor
- 0.98 to 19.69 feet (0.3 to 6 metres) for I-6 Sensor
- 0.98 to 32.81 feet (0.3 to 10 metres) for I-10 Sensor
- 1.64 to 49.21 feet (0.5 to 15 metres) for I-15 Sensor
- Measuring Uncertainty: 0.15” (4 mm) for I-6 Sensor
- Measuring Uncertainty: 0.23” (6 mm) at Distance of > 6 metres for I-10 Sensor & 0.23” (6 mm) at Distance of 0 to 10 metres for I-15
- Measuring Uncertainty: 0.39” (10 mm) at Distance of > 10 metres
Measuring Time
- Measuring Cycle: Min. 0 to 1 second
NPT Connection
- Installation: 1” NPT Male
- Installation: 1-1/2” NPT Male for I-3 & I-6 Sensor Front Thread
- Installation: 2” NPT Male for I-10 Sensor Front Thread
Operating Temperature
- -40° to 80° C (-40° to 176° F)
Output
- 3.8-22 mA
- 4-20 mA, 2-Wire
Power Supply
- 10-28 Vdc
Resolution
- 0.019” (0.5 mm) for I-3 Sensor
- 0.039” (1 mm) for I-6 & I-10 Sensor
- 0.05” (1.5 mm) for I-15 Sensor
Rotation
- Beam Angle: < 10° for I-3, I-6, I-10, I-15 Sensor
Turn-On Time
- Startup Time: 4 seconds Typical