J120-15622
Series: 120 Series Type J120 Model 15622 Pressure Switch Brand: United Electric Controls Ltd
Price
$1,421.00
CAD
Stock
100+ In Stock
- Model - 15622
- Adapter - Without Adaptor
- Factory Set Point - No Factory Set Point
- Agency Approvals - Without Approvals
- Tag - No Tag
- Mounting - No Mounting Kit
- Cleaning - Without Cleaning
Specifications
Adjustment Type
- Factory Set (Pre-Set)
Ambient Temperature Range
- -50° to 71° C (-58° to 160° F)
Applications
- Chemicals
- Oil & Gas Production
- Petrochemical
- Refinery
- Transmission
Approvals & Certifications
- ISO 9001
Approvals & Certifications
- ATEX Directive (94/9/EC) II 2 G Ex d IIC T6 Gb II 2 D Ex Tb IIIC T85° C Db IP66 Tamb: -40° to 75° C (-40° to 167° F) UL International Demko A/S (N.B.# 0539) Certificate # Demko 09-ATEX-0815573X Rev. 2 EN 60079-0, 60079-1, 60079-31 II 1 G Ex ia IIC T6 Ga
- CE
- CQST: CNEx15.2540X Ex d IIC T6 Gb Ex TD A21 T85° C IP66 Tamb. = -40° to 75° C (-40° to 167° F) GB3836.1,GB3836.2 & GB12476
- CRN
- CSA C22.2 No. 25 & 30 - File # E40857
- GOST-R 0Ex ia IIC T6 Ga x Tamb: -50° to 60° C (-58° to 140° F) NANIO CCVE Certification Center RU C-US.ГБ05.B.01185 ГOCT P MЭК 60079-11, ГOCT P MЭК 60079-0-2011, ГOCT 31610.26, IEC 60079-26
- GOST-R 1Ex d IIC T6 Gb x Tamb: -50° to 80° C (-58° to 176° F)
- GOST-U 1ExdIICT6X Tamb: -56° to 85° C (-68.8° to 185° F) СВIДОЦТВО #720 by DVSTS VE (TCCExEE)
- IECEx Certified Ex d IIC T6 Gb Ex Tb IIIC T85° C Db IP66 Tamb. = -40° to 75° C (-40° to 167° F) IEC 60079-0, 60079-1, 60079-31 Certificate # IECEx UL 03.0001X
- INMETRO Ex d IIC T6 Gb Ex Tb IIIC T85° C Db IP66 -40° ≤ Ta ≤ 75° C UL-BR 15.0179X ABNT NBR IEC 60079-0 ABNT NBR IEC 60079-1 ABNT NBR IEC 60079-31
- INMETRO Ex ia IIC T6 Ga -50° ≤ Ta ≤ 60° C UL-BR 15.0169X ABNT NBR IEC 60079-0 ABNT NBR IEC 60079-11 ABNT NBR IEC 60079-26
- KC
- KOSHA, Article 34 of Industrial Safety & Health Law Ex d IIC T6 -40° C < Tamb < 75° C, Certification# 10-AV4BO-0710
- Low Voltage Directive (LVD) 2006/95/EC
- PESO: CCEs Identification# P314108 / 1 EN 60079-0, 60079-1 Ex ia IIC T6 Ga, CCEs Identification# P305465 / 1 EN 60079-0, 60079-11, 60079-26
- PED: 97/23/EC
- TS ML041200701AE7, ML041200701BY3, ML041200701C40, ML041200701D31
- UL (C,US) 50 & 1203: Class I, Div. 1 & 2, Groups B, C, D, Class II, Div. 1 & 2, Groups E, F, G, Class III, Class I, Zone 1, Group IIB + H₂ T6
BSP Connection
- G 1/2” Male
Cover Material
- Gasketed Stainless Steel Tamper-Resistant Dial Cover
Deadband
- psi: 12 to 26 (kPa: 82.7 to 179.3, bar: 0.8 to 1.8)
Diaphragm Material
- Viton
Electrical Connectors
- 3/4” NPT
- Terminal Block
Electrical Contacts
- Normally Closed
- Normally Open
Electrical Rating
- 20 A, 125/250/480 Vac Resistive, 6 A at 30 Vdc, 0.5 A at 125 Vdc, 0.25 A at 250 Vdc
Enclosure Finish
- Epoxy Powder-Coated
Enclosure, Body Material
- Gasketed Die Cast Aluminum
Environmental Protection
- Flameproof
- Intrinsically Safe
- IP66
- Typical 4X
- Typical 7
- Typical 9
Mounting
- Pipe
- Surface
Name Plate, Tag Material
- Aluminum
- Stainless Steel
NPT Connection
- 1/2” NPT Male
- 1/4” NPT Female
- 1/4” NPT Male
O-Ring Material
- Viton
Overpressure & Static Pressure Limits
- Over Range Pressure - psi: 500 (kPa: 3,447, bar: 34.5)
Process Connection Material
- 316 Stainless Steel
Repeatability
- Set Point Repeatability: ± 1 % of Full Scale Range
Set Point - Decreasing
- bar: 1.4 to 13.8
- kPa: 137.9 to 1,379
- psi: 20 to 200
Set Point - Increasing
- bar: 1.4 to 13.8
- kPa: 137.9 to 1,379
- psi: 20 to 200
Shock
- Set Point Repeats after 15 G, 10 millisecond Duration
Storage Temperature
- -54° to 71° C (-65° to 160° F)
System Pressure
- bar: 0 to 34.47
- kPa: 0 to 3,447
- psi: 0 to 500
Vibration
- Set Point Repeats after 2.5 G, 5 to 500 Hz