Enclosure
- IP20 (IP21 with optional kit)
Installation Location
- For use at altitudes of (1000 m) or Less without derating
Ambient Temperature
- -10° to +50° C for above 45° C, there will be derating: please consult GE
Ambient Humidity
- 5 to 95 % Relative Humidity, Non-Condensing
Approvals & Certifications
- CE
- UL
- cUL
- C-Tick
- WEEE
- RoHS
- Suitable for use on a Circuit capable of delivering not more than 100,000 RMS symmetrical amperes for 230 V and 400 V
Rated Input AC Voltage
- 200-240 Vac, 1-Phase, 50/60 Hz, ± 10 % V
- 200-240 Vac, 3-Phase, 50/60 Hz, ± 10 % V
- 380-480 Vac, 3-Phase, 50/60 Hz, ± 10 % V
Maximum Voltage Imbalance
- 3 % of rated Supply Voltage
True Power Factor
- > 0.4 Nominal at Rated Load
Displacement Power Factor
Switching on Input Power Supply
Environment According to EN60664-1
- Overvoltage Category III/Pollution Degree 2
Rated Output Voltage
- 0 to 100 % of Supply Voltage
Output Frequency
- 0 to 200 Hz (Adv. Vector Control Plus Mode),
- 0 to 400 Hz (Volts/Hertz Mode)
Acceleration / Deceleration Time
Overload Current Rating
- 150 % of drive rated Current for 1 minute
Control Method
- Sinusoidal PWM Control (V/Hz with torque vector Control)
Switching Frequency Select (kHz)
Operation Method
- Keypad Operation: Hand, Off, Auto
- Digital Input: Programmable for Start/Stop, Forward/Reverse, Jog
- Timer Operation: Stop after predetermined time frame
- Link Operation: RS-485 Modbus RTU
Frequency Reference Setting
- Up or Down Buttons on keypad or external reference
Analog Input
- Built in Potentiometer
- 4-20 mA analogue Input
- 0-10 Vdc Analog Input
Preset Speeds
- 8 presets via Digital Inputs
Second Reference Setting
- Switch from speed reference 1 to reference 2 via Digital Input
Trim Reference Setting
- Available for speed reference offset via potentio meter, Voltage Input, or Current Input
Acceleration / Deceleration Time
- 0.05-3600 seconds (Two acceleration and deceleration rates are selectable via digital inputs. Acceleration and deceleration patterns can be selected from linear or S-Curve
DC Injection Braking
- Starting frequency: 0.0-400 Hz
- Braking level: 0-150 % of rated Current
- Braking Time: 0.0-60.0 seconds
Jump Frequency Control
- Two jump (or skip) frequencies via Parameter set to avoid mechanical vibration
Jogging Operation
- Operation via on Key or Digital Input (Forward or Reverse)
Auto-Restart After Power Failure
- Restarts the drive without stopping after instantaneous Power failure
Slip Compensation
- Maintains motor at constant speed with load fluctuations
Energy Savings
- Controls output voltage to minimize motor loss during constant speed operation
Start Mode Function
- This functionality smoothly catches a Spinning motor
Logic Controller Events
- Over 23 Types of Programmable events
Timers
- Array of 3 timers, Adjustable from 0.0 to 3600 sec
Logic Rules
- Array of 4 boolean logic rules
Logic Controller States
- Array of 20 logic Controller action States
Feedback Select
- No function, analogue Input 1, analogue Input 2, pulse Input, local bus reference
LEDs
- Red - Indicates an Alarm
- Yellow - Indicates a Warning
- Green - Drive is On
Monitor Units Available
- Frequency
- Current
- Voltage
- Power
- Horsepower
- % Load
- Speed
- Time
Monitoring Parameters Available