6100E Paperless Graphic Recorder

Brand: Eurotherm

The 6100E offers unrivalled input accuracy with a 125 Miliiseconds total sample rate for up to 6 input channels. Input channels are freely configurable to suit your process requirements.

Each instrument has an intuitive, touch screen display to enable operators to clearly view process data in varying formats, 8 MB of onboard flash data storage capability, ethernet communication and a compact flash drive.

Data is stored in a tamper-resistant binary format that can be used for secure, long term records of your process. 

The 6100E is truly designed for todays networked world and can be accessed via a Local Area Network, dialup connection, Intranet or Internet.
Features
  • 5.5" Colour TFT touchscreen display
  • USB 'Plug and Play'
  • 8 MB non-volatile flash memory
  • 125 Milliseconds parallel sampling/ 1 second update
  • Compact flash
  • Ethernet TCP/IP
  • Web server
  • Multi-language support (French, Dutch, German, Italian, Japanese, Korean, Portuguese, Russian and Simplified Chinese)

Specifications

Brand

Approvals & Certifications

  • CE
  • EMC
  • IEC 584.1, 751
  • UL

Approvals & Certifications

  • BS EN 61010, 60873, 61326

Battery Life

  • Replacement Period: 3-Years
  • Support Time (RTC): 1-Year Min. with Recorder UnPowered

Cable Length

  • Ethernet Communications: 325 feet (100 metres) - Max.

Channels

  • 12 Virtual Channels

Communication

  • 10/100 BaseT Ethernet (IEEE 802.3)
  • BOOTP
  • DHCP
  • FTP
  • ICMP
  • Modbus
  • SNTP
  • TCP/IP Protocols
  • USB

Current

  • AC Load Ratings, Max.
  • Thermocouple Data (Bias Current): 0.05 NA
  • Transmitter PSU: Max.

Display

  • Operator Interface (Size & Resolution): 5.5” 1/4 VGA (320 x 240 Pixels)
  • Operator Interface: TFT Color LCD with Cold Cathode Backlight, Fitted with Resistive, Analog, Touch-Panel

Electrical Connectors

  • Ethernet Communications (Termination): RJ45
  • Ethernet Communications: CAT5 Cable
  • Input Board: Edge Connector/Terminal Block

Environmental Protection

  • IP20
  • IP66

Humidity

  • Environmental Performance (Operation): 5 to 80 % Relative Humidity
  • Environmental Performance (Storage): 5 to 90 % Relative Humidity

Input

  • (Input Board) Channel to Ground, 1,500 Vac
  • (Input Board) Open Circuit Detection, ± 57 NA, Max.
  • DC Input Range: -150 to 150 mV
  • DC Input Range: -20 to 20 V
  • Input Board (Channel to Channel): 2,500 Vac
  • Input Board (Over Voltage Protection): 50 V Peak (150 V with Attenuator)
  • Input Board, Max.

Input Impedance

  • Input Board: > 10 megaohms for 38 mV, 150 mV, 1 V Ranges
  • Input Board: 65.3 kiloohms for 20 V Range

Insulation Resistance

  • Input Board: > 10 megaohms at 500 Vdc

Isolation

  • Input Board: 300 Vrms (Double, Basic Insulation)
  • Transmitter PSU (Channel to Channel, Channel to Ground): 100 Vrms or DC (Double, Basic Insulation)

Linearization

  • RTD Typical, Max.
  • Thermocouple, Max.

Mounting

  • Panel Mount: DIN 43700, ± 45°

Operating Temperature

  • Environmental Performance: 0° to 50° C (32° to 122° F)

Output

  • Transmitter PSU: 25 V Nominal

Power

  • AC Load Ratings, Max.

Power Requirement

  • 240 Vac
  • Maximum
  • Poly-Carbonmonofluoride / Lithium Batteries

Power Supply

  • 110-370 Vdc
  • 90-264 Vac, 45 to 65 Hz
  • Isolated Transmitter Power Supply: 110-240 V
  • Isolated Transmitter Power Supply: 24 V

Resistance

  • Input Board (Min. Break Resistance): 10 megaohms
  • Resistance Input (Lead Resistance): 0 to 6 kiloohms

Resolution

  • DC Input Range (Resistance): 5 to 148 milliohms
  • DC Input Range: 1.4 to 720 µV

RTD Type

  • Cu10
  • Cu53
  • JPt100
  • Ni100
  • Ni120
  • Pt100
  • Pt1000
  • Pt100A

Sample Rate

  • Update/Archive Rates (Input/Relay Output Sample Rate): 8 Hz

Sensor, Probe Type

  • B Thermocouple
  • C Thermocouple
  • D Thermocouple
  • E Thermocouple
  • G2 Thermocouple
  • J Thermocouple
  • K Thermocouple
  • L Thermocouple
  • Ni/NiMo Thermocouple
  • NiMo/NiCo Thermocouple
  • N Thermocouple
  • PlatineL Thermocouple
  • R Thermocouple
  • S Thermocouple
  • T Thermocouple
  • U Thermocouple

Shock

  • Environmental Performance: BS EN 61010

Storage Temperature

  • Environmental Performance: -20° to 60° C (-4° to 140° F)

Supply Voltage

  • 100-230 Vac ± 15 %, 47 to 63 Hz
  • Transmitter PSU: 110/120 Vac (100 mA)

Temperature Coefficient

  • 0 to 5 kiloohms Resistance Range: 30 ppm
  • -150 to 150 mV, -1 to 1 V Input Range: 25 ppm/°C
  • -20 to 20 V Input Range: 388 ppm/°C

Temperature Range

  • RTD Typical: -220° to 850° C (-364° to 1,562° F)
  • Thermocouple: -270° to 2,495° C (-454° to 4,523° F)

Update Time

  • Display, Trend Update: 1 second, Max.

Vibration

  • Environmental Performance (10 to 150 Hz): BS EN 60873

Voltage

  • AC Load Ratings, Max.
  • The Rate Impulse Voltage for Equipment on Nominal 230 V Mains is 2,500 V

show more