Price
$1,041.00 CAD
Stock
17 In Stock

  • Type of Detecting Component / Material - Rope / PTFE
  • Connection / Material - Flange DN 50 PN 16 / AISI 316L Stainless Steel (GB/T9119-2000)
  • Retained Seal / Operating Temperature - PTFE / -30° to 150° C
  • Electronics - 4-20 mA HART 2-Wires
  • Housing Material / Protection Class - Plastic / IP66
  • Wiring - M20 x 1.5
  • Display / Programming - YES

Specifications

Accuracy

  • ± 10 mm

Applications

  • Level Measurement of Liquid & Solid

BSP Connection

  • Antenna: G 1-1/2” A
  • G 2” A

Cable Entry

  • 1 x PG 13.5

Communication

  • Output Signal: HART

Consumption

  • Absorption: Max.

Current

  • Fixed Signal for Anomaly: 20.5 mA
  • Fixed Signal for Anomaly: 22 mA
  • Fixed Signal for Anomaly: 3.6 mA

Display

  • Resolution Display: 0.039” (1 mm)

Electrical Connectors

  • 1/2” NPT
  • M20 x 1.5

Enclosure, Body Material

  • AISI 316L Stainless Steel
  • Aluminum
  • Plastic PBT-FR

Environmental Protection

  • IP66
  • IP67

Flange Size - 2” (DN 50)

  • 2” (DN 50) - PN 16

Flange Size - 3” (DN 80)

  • 3” (DN 80) - PN 16

Flange Size - 4” (DN 100)

  • 4” (DN 100) - PN 16

Flange Size - 6” (DN 150)

  • 6” (DN 150) - PN 16

Frequency

  • Resistance to Vibration: 10 to 150 Hz
  • Ripple Allowed: 100 to 10,000 Hz

Humidity

  • < 95 % Relative Humidity

Input

  • Input Voltage: 15-36 Vdc for Supply 2-Wires Version
  • Input Voltage: 230 Vac ± 10 % for Supply 4-Wires Version
  • Input Voltage: 24 Vdc ± 10 % for Supply 4-Wires Version

Materials of Construction

  • Pole: AISI 316L Stainless Steel

Measuring Range

  • Maximum

Measuring Time

  • Interval of Measuring: Approximately 1 second

NPT Connection

  • Antenna: 1-1/2” NPT Male

Operating Temperature

  • -40° to 150° C (-40° to 302° F)

Output

  • 4-20 mA, 2 or 4-Wires

Pressure Range

  • bar: -1 to 40
  • kPa: -100 to 4,000
  • psi: -14.5 to 580

Resistance

  • Maximum

Resolution

  • 6 µA

Seat / Seal Material

  • Retained Seal: PTFE

Storage Temperature

  • -40° to 80° C (-40° to 176° F)

Update Time

  • Integration Time: 0 to 999 seconds
  • Interval of Updating: Approximately 1 second

show more